<?xml version="1.0" encoding="UTF-8"?> <rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:metadata_def="http://data.bioontology.org/metadata/def/" xmlns:dct="http://purl.org/dc/terms/"> <owl:NamedIndividual rdf:about="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/"> <rdf:type rdf:resource="http://www.w3.org/2004/02/skos/core#Concept"/> <skos:prefLabel xml:lang="en">PerkinElmer 2400 Series II CHNS and O elemental analyzer</skos:prefLabel> <metadata_def:mappingSameURI rdf:resource="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/"/> <metadata_def:mappingLoom>perkinelmer2400seriesiichnsandoelementalanalyzer</metadata_def:mappingLoom> <skos:definition xml:lang="en">A bench-top elemental analyser that is capable of operating in three modes: CHN, CHNS and Oxygen, is fully automated, and includes a 60 position autosampler. CHN and CHNS are determined via the classical Pregl-Dumas method where samples are combusted in a pureoxygen environment. Oxygen determination is based on the classical Unterzuacher method which incorporates the modifications of Oita, Conway and Culmo where samples are converted to carbon monoxide following after pryolisation and reaction with a platinised carbon reagent. The analyser has an accuracy of &lt;=0.3% and a precision of &lt;=02%. The analytical range is from 0.001 -3.6 mgs for C, 0.001-1.0 for H, 0.001-6 mgs for N and 0.001 to 2.0 mgs for S and O.</skos:definition> <skos:inScheme rdf:resource="http://vocab.nerc.ac.uk/scheme/SDNDEV/current/"/> <skos:broader rdf:resource="http://vocab.nerc.ac.uk/collection/L05/current/LAB01/"/> <dct:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2022-04-27T16:55:15</dct:date> </owl:NamedIndividual> <rdf:Description rdf:about="http://vocab.nerc.ac.uk/collection/L05/current/LAB01/"> <skos:narrower> <rdf:Description rdf:about="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/"> <metadata_def:mappingSameURI rdf:resource="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/"/> </rdf:Description> </skos:narrower> </rdf:Description> </rdf:RDF>
<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:metadata_def="http://data.bioontology.org/metadata/def/" xmlns:dct="http://purl.org/dc/terms/">
  <owl:NamedIndividual rdf:about="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/">
    <rdf:type rdf:resource="http://www.w3.org/2004/02/skos/core#Concept"/>
    <skos:prefLabel xml:lang="en">PerkinElmer 2400 Series II CHNS and O elemental analyzer</skos:prefLabel>
    <metadata_def:mappingSameURI rdf:resource="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/"/>
    <metadata_def:mappingLoom>perkinelmer2400seriesiichnsandoelementalanalyzer</metadata_def:mappingLoom>
    <skos:definition xml:lang="en">A bench-top elemental analyser that is capable of operating in three modes: CHN, CHNS and Oxygen, is fully automated, and includes a 60 position autosampler. CHN and CHNS are determined via the classical Pregl-Dumas method where samples are combusted in a pureoxygen environment. Oxygen determination is based on the classical Unterzuacher method which incorporates the modifications of Oita, Conway and Culmo where samples are converted to carbon monoxide following after pryolisation and reaction with a platinised carbon reagent. The analyser has an accuracy of &lt;=0.3% and a precision of &lt;=02%. The analytical range is from 0.001 -3.6 mgs for C, 0.001-1.0 for H, 0.001-6 mgs for N and 0.001 to 2.0 mgs for S and O.</skos:definition>
    <skos:inScheme rdf:resource="http://vocab.nerc.ac.uk/scheme/SDNDEV/current/"/>
    <skos:broader rdf:resource="http://vocab.nerc.ac.uk/collection/L05/current/LAB01/"/>
    <dct:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2022-04-27T16:55:15</dct:date>
  </owl:NamedIndividual>
  <rdf:Description rdf:about="http://vocab.nerc.ac.uk/collection/L05/current/LAB01/">
    <skos:narrower>
      <rdf:Description rdf:about="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/">
        <metadata_def:mappingSameURI rdf:resource="http://vocab.nerc.ac.uk/collection/L22/current/TOOL0908/"/>
      </rdf:Description>
    </skos:narrower>
  </rdf:Description>
</rdf:RDF>